SDRLF DUPLEX LARGE FLOW RATE RETURN LINE FILTER SERIES
SDRLF series filter is composed of two single Bowl filters and a 2 position 6-way directional valve. It is simple in construction and easy to use. There is a by-pass valve and a contamination indicator in it, for protecting the hydraulic system safety.The feature of this filter allows continues operation even during element is changed for which is clogged by contaminants.
After opening the balance valve and then turn the directional valve, the other filter begins to work; the clogged element should be changed in time.
This series filter is widely used in the hydraulic systems of heavy-duty mining and metallurgical machines.
Model Description
Technical Data
Model | Flow rate (L/min) | Accuracy (μm) | Diameter (mm) | Pressure (MPa) | Pressure lost(MPa)) | By pass open value | Sender device power(V/W) | weight (kg) | Filter element | Qty of element |
Initial | Max |
SDRLF-A1300×*P | 1300 | 1 3 5 10 20 30 | Ф100 | 1.6 | 0.2 | 0.35 | 0.4 | 24V/48W 220V/50W | 610 | SFX-1300×* | 1×2 |
SDRLF-A2600×*P | 2600 | Ф150 | 820 | 2×2 |
SDRLF-A3900×*P | 3900 | Ф200 | 850 | 3×2 |
SDRLF-A6500×*P | 6500 | Ф250 | 915 | 5×2 |
SDRLF-A7800×*P | 7800 | Ф250 | 960 | 6×2 |
SDRLF-A9100×*P | 9100 | Ф250 | 990 | 7×2 |
Note: * for the filter accuracy, if the use of media for the water-ethylene glycol, with the transmitter. The filter model is SDRLF · BH-A2600X * P, the filter model is SFX · BH-130X *. |
Installation Dimensions
External flange connection dimensions
Model | Sizes (mm) | Qty of element |
B1 | D1 | D2 | D3 | D4 | D5 | D6 | H1 | H2 | H3 | H4 | H5 | H6 | H8 | H9 | L1 | L2 |
SDRLF-A1300×*P | 900 | 450 | 325 | 245 | 100 | 14 | G3/4 | 1200 | 250 | 230 | 365 | 230 | 150 | 200 | 10 | 27 | 80 | 2 |
SDRLF-A2600×*P | 1125 | 555 | 500 | 412 | 150 | 18 | G1 | 1280 | 250 | 275 | 225 | 260 | 15 | 29 | 100 | 4 |
SDRLF-A3900×*P | 200 | 6 |
SDRLF-A6500×*P | 1400 | 600 | 610 | 508 | 250 | 23 | 1500 | 350 | 450 | 250 | 270 | 325 | 18 | 31 | 110 | 10 |